Checking Cold-Formed Stud Model Inputs
Identify which direction the section resists the modeled action. Use the example below to practice the review and record an output that another reviewer can reproduce.
Inputs and Prerequisites
Stud layout, unbraced lengths, loading direction and supplier section data.
Review Workflow
- Pressure
- Stud spacing
- Line load
- Reactions
- Identify which direction the section resists the modeled action.
- Record restraint, bridging and whether sheathing is assumed effective.
- Transfer tributary loading using consistent length units.
Worked Example
A nominal lateral pressure of 0.6 kPa on studs at 400 mm gives 0.24 kN/m per stud for an interior strip. In a 3 m simple-span check the two ideal reactions are 0.36 kN each.
Output Checks and Common Errors
Confirm effective section properties and governing buckling checks independently of the tributary-load calculation.
Official References
- AISI cold-formed steel standards committees
Locate AISI S240 for structural framing and check the edition and related member design standard.