Advanced

Separating Construction and Final Floor Deck Loads

Calculate nominal wet concrete weight for the represented geometry. Use the example below to practice the review and record an output that another reviewer can reproduce.

Inputs and Prerequisites

Deck layout, pour thickness, concrete density, span and shoring assumptions.

Review Workflow

  1. Pour geometry
  2. Wet weight
  3. Construction stage
  4. Final stage
  1. Calculate nominal wet concrete weight for the represented geometry.
  2. Record temporary construction actions and shoring separately.
  3. Build an independent final-stage load case for the completed assembly.

Worked Example

For an extra 35 mm of normal-weight fresh concrete at an assumed 24 kN/m³, the increase is 0.84 kPa. A 2 m by 3 m tributary patch therefore adds 5.04 kN before other actions. Corrugation volume and construction loading require their own entries.

Output Checks and Common Errors

Check the deck stage and whether table loads include deck and concrete self-weight.

Official References