Intermediate

Reviewing Model Actions in IDEA StatiCa

Trace member-end actions from the analysis report into the connection model. Use the example below to practice the review and record an output that another reviewer can reproduce.

Inputs and Prerequisites

Connection sketch, analysis results, load combinations and a declared local-axis convention.

Review Workflow

  1. Analysis forces
  2. Local axes
  3. Connection input
  4. Equilibrium
  1. Trace member-end actions from the analysis report into the connection model.
  2. Document member orientation and the location where actions act.
  3. Check reactions and compare a simple limiting case before accepting detailed outputs.

Worked Example

An assumed 40 kN beam shear acts at a reference location 75 mm from the support face. Moving the action to that face requires tracking a 3.0 kN·m moment about the relevant axis. Confirm the model convention before entering an equivalent load.

Output Checks and Common Errors

Avoid counting the transfer eccentricity twice. Check that all modeled members have the intended restraints and load combinations.

Official References

Related Video

IDEA StatiCa: Design and Code Check of a Seismic Connection (YouTube)