Beginner

Canadian Structural Design Loads and Load Combinations

Build a load register before entering combinations in an analysis program. Write down what each load represents, its units, its direction and which parts of the structure receive it.

Inputs and Prerequisites

A tributary framing sketch, clear spans, separate area loads and the locally adopted design-code edition.

Structural Load Cases and Load Paths

  1. Area load
  2. Tributary strip
  3. Beam
  4. Support reactions
  1. Separate loads by action so that permanent loads, occupancies and environmental loads can be combined with their own factors and accompanying terms.
  2. Trace each area load through the slab or deck to its supporting member. Confirm tributary width before converting kPa to kN/m.
  3. Record the adopted code edition, local amendments, limit state and combination assumptions beside the model cases.

Worked Example for a Simply Supported Beam

Use a hypothetical permanent area load of 1.5 kPa and a separate imposed area load of 2.0 kPa. A 3 m tributary width gives independent line loads of 4.5 kN/m and 6.0 kN/m. For a 6 m simply supported beam under uniform load, each end receives 13.5 kN from the permanent case and 18.0 kN from the imposed case. Add any separate beam self-weight to the permanent case. Select combination factors from the adopted provisions for the project and the limit state being checked.

Output Checks and Common Errors

Compare each pair of model reactions with the total load from its own case before checking combined results. Confirm the code edition and jurisdiction when adapting an archived classroom example.

Official References