Structural Masonry Wall Design and Detailing
Trace a masonry wall load path, calculate an idealized support reaction and review how reinforcement continuity is documented.
Inputs and Prerequisites
Wall plans and sections, lateral loads, attachment details and the adopted masonry design basis.
Design and Review Workflow
- Lateral load
- Wall strip
- Top and bottom restraints
- Supporting structure
- Identify the assumed spanning direction and verify the restraints shown on the drawings.
- Read reinforcement, grout and connection details together. Follow continuity around openings and at supports.
- Record the applicable masonry standard, edition and design assumptions.
Worked Example for a Vertically Spanning Masonry Strip
A hypothetical one-metre-wide wall strip is simply supported at the top and bottom. A uniform pressure of 1.2 kPa over the 3 m height gives 3.6 kN of lateral load. Each support receives 1.8 kN in this idealized example.
Output Checks and Common Errors
Compare the reactions with the attachment details. Review strength, serviceability and load transfer around openings using the adopted design basis.
Official References
- National Building Code of Canada 2020, Division B Part 4
Locate the masonry structural design provisions and the referenced standard for that edition.
Related Calculation Workbooks
- Masonry Pier Checks
A pier design worksheet with distinct masonry shear and sliding resistance sections.
- Shelf Angle Support Checks
Collects shelf-angle load, section classification and deflection checks.