Advanced

Checking Units in Mathcad Engineering Worksheets

Enter dimensions and loads with units. Use the example below to practice the review and record an output that another reviewer can reproduce.

Inputs and Prerequisites

Mathcad Prime, a reference hand calculation and clearly identified unit-bearing variables.

Review Workflow

  1. Quantity inputs
  2. Unit algebra
  3. Display units
  4. Hand check
  1. Enter dimensions and loads with units.
  2. Report output in the drawing or design unit system.
  3. Change only the display units and confirm the same physical result.

Worked Example

Enter 5 kN and an eccentricity of 80 mm. Their product is 400 kN·mm, which displays as 0.40 kN·m. Typing an unqualified 80 instead would lose a length unit.

Output Checks and Common Errors

Use a worksheet label for the physical basis of each number, including any assumed action or sign.

Official References

Related Video

PTC Mathcad Prime: How to Use Units in Engineering Calculations (YouTube)