Reviewing FRP Laminate Layouts for Concrete Repair
Map laminate strips against reinforcement and intended force direction. Use the example below to practice the review and record an output that another reviewer can reproduce.
Inputs and Prerequisites
Assessment sketch, proposed fiber direction and supplier system documentation.
Review Workflow
- Existing member
- Fiber layout
- Termination
- Review record
- Map laminate strips against reinforcement and intended force direction.
- Record terminations and substrate conditions.
- Distinguish installed coverage from effective resistance.
Worked Example
Four proposed strips each 100 mm wide by 2.4 m long cover 0.96 m² of nominal face area. If a 200 mm obstruction shortens one strip, coverage becomes 0.94 m². Log the affected termination separately.
Output Checks and Common Errors
Verify development, substrate condition and the complete qualified system with the responsible engineer.
Official References
- ACI Committee 440 resources on external FRP strengthening
Find the external FRP strengthening documents for the proposed system.
Related Video
Strengthening Concrete Structures with FRP Systems (YouTube)