Inputs and Prerequisites

A small physical model, analytical elements and published model tolerance assumptions.

Review Workflow

  1. Physical framing
  2. Analytical endpoints
  3. Connectivity check
  4. Model handoff
  1. Compare analytical endpoints at intended joints.
  2. Check position and role of columns, beams and restraints.
  3. Record intentional offsets separately from unintended disconnected nodes.

Worked Example

An assumed beam endpoint is at elevation 3.000 m, and the target analytical node is at 3.020 m. The 20 mm mismatch must be resolved or modeled as an intentional offset. A physical solid overlap does not prove analytical connectivity.

Output Checks and Common Errors

Confirm identical coordinates or an explicit modeled link before checking load transfer.