Checking Deck Continuity at Roof Openings
Mark which ribs are interrupted by the opening. Use the example below to practice the review and record an output that another reviewer can reproduce.
Inputs and Prerequisites
Roof deck framing plan, sheet direction, proposed opening and support details.
Review Workflow
- Rib direction
- Cut ribs
- Header
- Supporting frame
- Mark which ribs are interrupted by the opening.
- Identify the detail that transfers cut-rib reactions into supporting framing.
- Compare revised support conditions against the applicable roof-deck data.
Worked Example
An assumed opening interrupts two ribs, each modeled as delivering a 0.9 kN service reaction to a header. The header receives 1.8 kN from those reactions. Add its self-weight and track where the header reactions go.
Output Checks and Common Errors
Confirm that the assumed header exists and that deck shear transfer around the opening is addressed separately.
Official References
- Steel Deck Institute design manuals
Find the manual for the specified deck application. Use the matching manufacturer tables for product-specific ratings.