Roof Snow Loads and Snow Drift
Build a roof load map with climate data, roof geometry and the adopted code basis.
Inputs and Prerequisites
Roof plan and elevations; adopted code edition; location-specific snow and associated rain inputs.
Work Steps
- Inputs
- Model or detail
- Independent check
- Review record
- Identify upper and lower roofs, steps and obstructions.
- Record each climate input and coefficient’s source.
- Separate uniform roof load from localized drift cases and assign the correct loaded area.
Worked Example or Review Exercise
The Linkoteq NBCC 2020 uniform benchmark uses 2.40 kPa ground snow, 0.40 kPa associated rain and a 0.80 basic roof factor, with the remaining stated factors at 1.00. The example gives 2.32 kPa. Draw a separate load diagram for any drift case required by the project.
Output Checks and Common Errors
Compare total loads and reactions to a hand estimate for the uniform case. Check whether roof steps or obstructions also require a drift case.
Official References
- NRC National Building Code of Canada 2020
Use the publisher’s source to verify the scope, assumptions and applicable edition.
Related Calculation Workbooks
- Roof Snow and Drift Worksheets
Compare the uniform, parapet and lower-roof snow load worksheet layouts.
- NBCC 2005 Basic Snow and Drift
Provides separate layouts for roof snow, drifts at obstructions and loading on a lower roof.
- NBCC 2005 Roof Snow Accumulation
Calculates historical snow accumulation scenarios for several roof geometries.
- Roof Snow Drifts at Canopies and Equipment
An NBCC 2005 design aid with obstruction and roof equipment scenarios.
- Uniform Roof Snow and Drift (Alternate File)
Shows separate uniform, parapet and lower-roof loading layouts.